HI8720 ORP panel mounted controller is ideal for process control monitoring in a wide range of industrial applications, allowing for the selection of a set point for oxidizing or reducing dosage.

  • Auto-diagnostic tests for electrode and instrument status.
  • Displays values on the easy to read LCD.
  • A removable, transparent splash-proof cover protects the front panel.
Tempi di spedizione
Non a stock, spedizione prevista entro 10 giorni lavorativi
Garanzia diretta dal produttore
Assistenza clienti sempre a disposizione
Maggiori informazioni
Specifiche tecniche
Recensioni
Downloads
Info Ordine

Auto-Diagnostic Feature

Built-in autodiagnostic functions to enable the user to check and troubleshoot any malfunctions. The functions are made via front panel keys to isolate the cause of malfunction.

Consent Contacts

These contacts (maximum 2A, 220 V) are for reduction and oxidation reactions when the pH controller is used with an ORP Controller. In these applications, the consent contacts of both meters are connected together to link the ORP and pH controllers so that ORP dosage will occur only if the actual pH value is correct, to avoid overdosage of oxidants or reductants that can lead to pollution.

Alarm Contacts

If the measured ORP is not within the tolerance of the set value, the alarm contact is closed. This can occur if there is insufficient dosage or if there is overdosage.

Outputs

You can choose the output configuration for connecting a recorder or a PLC, between 0-20 or 4-20 mA

ORP Dosing Consent Device

When used in conjunction with the HI 8710 pH controller, the ODCD (ORP dosing consent device) function (featured by the HI 8710) will ensure that the ORP dosage will start only when the pH level is correct.

Robust Design

A removable, transparent splash-proof cover protects the front panel.

Scala mV: ±1000 mV
Risoluzione mV: 1 mV
Accuratezza mV: ±0.5%
Calibrazione mV (ORP): Offset: ±2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer
Relè di Dosaggio mV (ORP): 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
Set Point mV (ORP): 0.00 to 14.00 pH
Set Point Relè Allarme: 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
Scala Relè Allarme: 10 to 300 mV
Sovradosaggio: Adjustable, from 5 min to 60 min with knob or Disable by wire strap ‐ on rear panel
Segnale Ingresso Analogico: 4 to 20 mA
Segnale Uscita Analogica: ±5 Vcc; 150 mA max load for amplified electrodes
Retroilluminazione: Continuous ON
Componenti Esterne Incluse: Black anodized aluminum body; front and back with ABS; transparent splash‐proof front cover
Alimentatore: 115 or 230 Vac; 60/50 Hz
Condizioni di Utilizzo: ‐10 to 50 °C (14 to 122 °F); RH max 95% non condensing
Dimensioni: 141 x 69 mm (5.6 x 2.7”)
Peso: 1 kg (2.2 lb.)