The HI1413S/50 is a glass body, single reference junction pH electrode made with low temperature glass and a screw connector. This electrode has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell. The open junction design resists clogging and the probe's flat tip makes it ideal for pH measurements on surfaces such as skin, leather, agar plates, and paper.

  • Open Junction
  • Flat Tip
  • Viscolene Gel Electrolyte
Tempi di spedizione
Non a stock, spedizione prevista entro 10 giorni lavorativi
Garanzia diretta dal produttore
Assistenza clienti sempre a disposizione
Maggiori informazioni
Specifiche tecniche
Recensioni
Downloads
Info Ordine

Low-Temperature Glass Formulation

The glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general-purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass decreases in the sample, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter.The HI1413S/50 is suitable to use with samples that measure from 0 to 50°C.

Flat Glass Tip

A flat tip is recommended to optimize surface contact for measurement on skin, leather, agar plates, paper, and samples that cannot easily be penetrated.

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature-dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

Open Junction Reference

Suspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable readings.

Screw Connector

The HI1413S/50 uses a screw connector. Screw connectors attach directly to the meter and can also be made interchangeable with other meters by using a Hanna BNC extension cables.

Descrizione: pH electrode
Scala di Misura: pH: 0 to 12
Scala Temperatura: 0 to 50°C (32 to 122°F) - LT
Tipo Cella di Riferimento: Single, Ag/AgCl
Tipo/Portata Giunzione: Open
Tipo di Elettrolita: Viscolene
Materiale del Corpo: Glass
Tipo di Vetro: Low Temperature
Punta: flat
Matching Pin: no
Pressione Max.: 0.1 bar
Sensore di Temperatura: no
Diametro Sonda: 12 mm
Cavo: coaxial (0.5 m)
Tipo di Connettore: screw cap
Amplificatore: no
Utilizzo: emulsions, leather, paper, skin, surface