€170,00 + 22% IVA
The HI1285-8 multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe.
Use with the HI981420 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
Hanna Instruments offers a wide variety of electrodes that are designed for many different applications. The sensing material, body material, and connection type used are just some of the design considerations.
The pH electrode circuit has a built-in amplifier that serves to reduce the effects of electrical noise on the high impedance-pH measurement. Electrical noise can come from motors and pumps that are common in greenhouses. The single reference junction design of the pH electrode has a cloth junction that allows ion movement between the inner gel electrolyte and the sample being measured. The advantage of the cloth junction is that it can be extracted from the probe, exposing a fresh surface when readings become drifty or erratic. These features make this probe ideal for use in fertilizer solutions.
EC/TDS readings are performed by a two-pin amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins determines the amount of dissolved ionic solids present.
pH and EC/TDS readings must be temperature compensated in order to obtain accurate results. The built-in temperature sensor of the HI1285-8 provides a speedy temperature reading which is then used to adjust the pH and EC/TDS results accordingly.
The polypropylene body of the HI1285-8 houses all three sensors within a sturdy, single body design. This body material is suitable for a wide range of applications and excels in harsh grow environments due to its durability. The polypropylene plastic is a high-quality plastic that is chemically resistant to many aggressive chemicals and minimizes breakage due to accidental bumping or dropping of the electrode.
The HI1285-8 uses a DIN connector. This probe is recommended for use with the HI981420 GroLine Hydroponic Nutrients Monitor for pH, EC, TDS, and Temperature.
Reference: single, Ag/AgCl
Junction / Flow Rate: cloth
Electrolyte: gel
Max Pressure: 0.2 bar
Range: pH: 0 to 13/EC
Recommended Operating Temperature: 0 to 50หC (32 to 122หF) - LT
Tip / Shape: spheric (dia: 8.5 mm)
Temperature Sensor: yes
Amplifier: yes
Body Material: polypropylene
Cable: 7-pole; 1 m cable (3.3')
Recommended Use: hydroponics, aquaponics, greenhouses
Connection: DIN
Special Note: *To be used with HI981420 GroLine monitor