Home > Prodotti > pHmetri > Panel-mounted ORP Digital Controller - mV600

SKU: mV600-02-web

Panel-mounted ORP Digital Controller - mV600

The mV600 controllers have been engineered with a number of outstanding features to meet all of your process control needs. mV600 offer a multitude of possibilities from ON/OFF or proportional dosage to analog recorder output and alarm. A host of self-testing features and user-friendly functions make mV600 a great value.

  • Accurate, reliable and simple to install.
  • Fully programmable microprocessor memory.
  • Wiring the controllers is simple with extractable terminal modules
Tempi di spedizione
#N/A
Garanzia diretta dal produttore
Assistenza clienti sempre a disposizione
Maggiori informazioni
Specifiche tecniche
Recensioni
Downloads
Info Ordine

The product is a real time microprocessor-based ORPcontroller. It provides accurate measurements, flexible ON/OFF or proportional control capabilities.

mV600 Series ORP Controller's FEATURES/BENEFITS:

Display 

  • Large LCD with 4 ½ 17 mm digits and 3 ½ 10 mm digits.

Fail Safe Alarm System

  • Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.

Differential Input

  • In a system with poor grounding, it is possible to have a ground current flowing through the reference junction. This can cause a rapid degradation of the electrode. The Hanna differential input reduces the likelihood of ground loops.

Proportional Control

  • Slows the pump down when the measured ORP level approaches the set value, which ensures precise dosage and avoids costly waste of chemicals due to overdosage.

Analog Output

  • To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a hard copy of the results on demand.

PC Connectivity

  • RS232C port allows for connection to a PC. Data transmission from the instrument to the PC is possible with the HI 92500 Windows® compatible application software offered by Hanna Instruments.

Custom Programs

  • Hi-tech microprocessor puts a host of variables at your disposal to fine tune your process, save on chemicals and meet regulatory requirements.

Good Laboratory Practice (GLP) 

  • calibration date andtime and the mV calibration points used 

Relays

  • 1 or 2 output relays for low conductivity or highconductivity dosage (COM, NO and NC contacts) and 1output relay for alarm condition (COM, NO and NC con-tacts)

Calibration

  •  Automatic  1 or 2 points at 0, 350 and 1900 mV.

Input

  • ORP electrode with BNC connector.

 

 

Scala mV: ±2000 mV
Risoluzione mV: 1 mV
Accuratezza mV: ±2 mV
Calibrazione mV (ORP): automatic, two point, at 0 and 350 or 1900 mV
Scala Temperatura: -9.9 to 120°C
Risoluzione Temperatura: 0.1°C
Accuratezza Temperatura: ±0.5°C
Segnale Uscita Analogica: galvanically isolated: 0-1 mA, 0-20 mA and 4-20 mA, 0-5 VDC, 1-5 VDC and 0-10 VDC
Segnale Uscita Digitale: RS232 bi-directional optoisolated
Consumo di Energia: 15 VA
Fusibile di protezione : 5A, 250V fast fuse
Frequenza Massima Oscillazione: 4 MHz
Dimensioni foro pannello: 140 x 140 mm
Alimentatore: 230 ±10% VAC , 50/60 Hz
Condizioni di Utilizzo: 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensioni: 144 x 144 x 170 mm
Peso: 1.6 kg (3.5 lb.)
Informazioni Ordine: Each mV 600 model is supplied complete with mounting brackets and instructions.