Home > Prodotti > Titolatori > Sonde e Accessori > Photometric Probe for Colorimetric Titrations at 470 nm - HI900604

SKU: HI900604 Categorie: ,

Photometric Probe for Colorimetric Titrations at 470 nm - HI900604

511,00 + 22% IVA

10000 disponibili (ordinabile)

Guadagna 511 punti
Richiedi informazioni
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900604 photometric electrode for when a color change is still the best solution.
    • High color sensitivity in a compact design
    • Chemically resistant glass-body construction
    • Stable blue LED (470 nm) light source with low drift
Tempi di spedizione
Non a stock, spedizione prevista in 3-4 settimane lavorative
Garanzia diretta dal produttore
Assistenza clienti sempre a disposizione
Maggiori informazioni
Specifiche tecniche
Recensioni
Downloads
Info Ordine
The HI900604 photometric electrode has a blue LED with a wavelength of 470 nm as a light source. This wavelength of light is useful for determining a yellow endpoint when using indicators such as bromophenol blue during a volumetric titration. The HI900604 can be used for a variety of applications, including:
  • Carboxyl end groups in polymers according to ASTM D7409.
HI900604 Photometric Probe Sample cell

LED at 470 nm

HI900604 uses a LED that emits light at 470 nm (blue color). This high quality LED will provide long term use since it takes thousands of hours for the LED intensity to dim naturally.

Reflective Measurement

The HI900604 contains a glass flow through cell, which the sample fills. The LED shines light at 470 nm through the sample, which is reflected back by a platinum mirror sealed in the glass tip of the probe. The fixed path length of the reflective measurement allows for high color sensitivity in a compact design.

Automatic Temperature Compensation

All readings are compensated for the changes in temperature of the sample from 0 to 75oC (32 to 167oF) to provide for accurate and repeatable measurements.

 HI900604 Photometric Probe Design

Glass-Body Probe

HI900604 probe has a glass-body that offers excellent chemical resistance against organic solvents. These solvents can be found in samples and can attack different forms of plastics.

Steel Shielding

The electronics of the probe are located in a steel shielding, which is covered by the glass-body. The steel sheilding of the probe also blocks out ambient light and protects against electronic interference.

12 mm Diameter Probe Body

HI900604 has a probe diameter of 12 mm (1/2"), which is the standard size for most pH/ORP electrodes. The 12 mm probe will fit in most electrode holders.

 HI900603 with HI932 Titration System

BNC Connector

HI900604 has a BNC connector for connecting a pH/mV input of a meter. The mV range for the probe is from 10 to 1100 mV.

PS/2 Mini-DIN Connector

A PS/2 connector is used for supply power to the probe. The HI931and HI932 potentiometric titration systems have a ps/2 power output for the probe to be connected to. The HI900932 is a PS/2 Y-splitter that is also available and allows for multiple probes to use one power source.

LED Calibration Trimmer

Although the LED provides a very long life, it does slowly dim over time. A trimmer located in the head of the probe can be used to adjust the output intensity. This allows the probe to be recalibrated, ensuring accurate measurements. The probe is placed in DI or distilled water and the trimmer adjusted until 1000 mV (100% transmittance) is displayed.

Scala mV: 10 to 1100 mV
Lunghezza d'Onda Sonda Fotometrica: 470 nm
Sorgente Luminosa Sonda Fotometrica: LED
Ciclo di Misura: LED pulsed at 1 kHz
Rilevatore Luminoso Sonda Fotometrica: silicon photocell
Compensazione Temperatura: automatic from 0 to 75ยฐC (32 to 167ยฐF)
Materiale del Corpo: glass
Lunghezza Complessiva: 120 mm / 200 mm
Diametro Sonda: 12 mm
Tipo di Connettore: BNC
Alimentatore: PS/2
Condizioni di Utilizzo: 0 to 50ยฐC (32 to 122ยฐF)
Informazioni Ordine: HI900604 photometric probe is delivered in a plastic case and is supplied with a trimmer tool, quality certificate, and instruction manual.

Non ci sono download disponibili per questo prodotto
Non ci sono informazioni sull'ordine di questo prodotto
cartmagnifiercrosschevron-right-circle

Non stavi lasciando il carrello cosรฌ, vero?

Inserisci i tuoi dettagli qui sotto per salvare il tuo carrello per dopo. Chissร , forse ti invieremo anche un dolce codice sconto :)